Persona: Bravo Yagüe, Juan Carlos
Cargando...
Dirección de correo electrónico
ORCID
0000-0002-9961-4314
Fecha de nacimiento
Proyectos de investigación
Unidades organizativas
Puesto de trabajo
Apellidos
Bravo Yagüe
Nombre de pila
Juan Carlos
Nombre
14 resultados
Resultados de la búsqueda
Mostrando 1 - 10 de 14
Publicación Assessment of molecularly imprinted polymers as selective solid-phase extraction sorbents for the detection of cloxacillin in drinking and river water(MDPI, 2023-11-03) Collado, Eduardo José; Paniagua González, Gema; Bravo Yagüe, Juan Carlos; Fernández Hernando, Pilar; Garcinuño Martínez, Rosa MªThis paper describes a new methodology for carrying out quantitative extraction of cloxacillin from drinking and river water samples using a molecularly imprinted polymer (MIP) as a selective sorbent for solid-phase extraction (MISPE). Several polymers were synthesized via thermal polymerization using cloxacillin as a template, methacrylic acid (MAA) as a functional monomer, ethyleneglycoldimethacrylate (EGDMA) as a cross-linker and different solvents as porogens. Binding characteristics of the adequate molecularly imprinted and non-imprinted (NIP) polymers were evaluated via batch adsorption assays following the Langmuir and Freundlich isotherms and Scatchard assays. The parameters related to the extraction approach were studied to select the most appropriate polymer for cloxacillin determination. Using the optimized MIP as the SPE sorbent, a simple sample treatment methodology was combined with high-performance liquid chromatography (HPLC) to analyze cloxacillin residues in drinking and river water. Under the optimum experimental conditions, the MISPE methodology was validated using spiked samples. The linearity for cloxacillin was assessed within the limits of 0.05–1.5 g L1 and the recovery percentage was higher than 98% (RSD < 4%). The limits of detection and limits of quantification were 0.29 and 0.37 g L1 and 0.8 and 0.98 g L1 for drinking and river water, respectively. The selectivity of MIP against other ß-lactam antibiotics with similar structures (oxacillin, cefazoline, amoxicillin and penicillin V) was studied, obtaining a good recovery higher than 85% for all except cefazoline. The proposed MISPE-HPLC methodology was successfully applied for the detection of cloxacillin in drinking water from Canal de Isabel II (Madrid) and river water from the Manzanares River (Madrid).Publicación Methacrylic acid-ethylene glycol dimethacrylate polymeric sorbent for the removal of estrogens from water(['Estrogens', 'Removal', 'Polymer', 'Sorbent', 'Waters', 'Balaban Publishers – Desalination Publications'], 2018-11) Gallego, Alejandrina; Bravo Yagüe, Juan Carlos; Paniagua González, Gema; Fernández Hernando, Pilar; Garcinuño Martínez, Rosa MªThe presence of estrogens in environmental waters can cause adverse effects to aquatic organisms. In the last years, diverse researches have been focussed on the development of cost-effective methods for the removal of these compounds in water. In this paper, a series of methacrylic acid-ethylene glycol dimethacrylate polymers with different monomers ratio were synthesised by photochemical (UV irradiation at 365 nm) or thermal (oven at 60°C) initiation. Batch and continuous flow experiments were carried out to evaluate the capacity of these polymers to adsorb estradiol (E2), ethinylestradiol (EE2) and dienestrol (DEN). Adsorption isotherm studies revealed that Langmuir isotherm model was fitted with a better correlation than Freundlich isotherm. Finally, continuous flow experiments were carried out by microcolumn studies to check the suitability of the polymeric sorbent for the removal of estrogens from real water samples. When continuous removal experiments at 8 mL min–1 flow rate were carried out, breakthrough adsorption capacities of 28.5, 38 and 69.7 mg g–1 for E2, EE2 and DEN, respectively, were achieved.Publicación Detecting ultraviolet C radiation under polyethylene terephthalate (PET) packaging by thermoluminescence analysis using commercial dosimeters(Elsevier, 2024-03-07) Correcher, V.; Boronat Castaño, Cecilia; Bravo Yagüe, Juan CarlosFood irradiation is a proven technology that enhances food quality and safety by removing microorganisms and extending shelf life. Ultraviolet C radiation (UVC) has recently attracted interest due to its potential to inactivate foodborne pathogens. It relies on several advantages; however, there is limited research on its efficacy and safety particularly concerning food packaging materials such as polyethylene terephthalate (PET). This study reports on the effect of UVC radiation on commercial thermoluminescence dosimeters (namely, TLD-100, TLD-200, TLD-400 and GR-200) placed under PET films with different thicknesses (0.10, 0.42, and 0.60 mm). The results indicate the potential use of these materials for the detection of UVC radiation passing through the randomly selected PET samples. Fourier transform infrared spectroscopy assesses potential structural and chemical alterations in the PET induced by UVC exposure.Publicación Analysis of total arsenic content in purchased rice from Ecuador(Czech Academy of Agricultural Sciences, 2019-12-31) Atiaga Franco, Oliva L.; Otero, Xose L.; Gallego Picó, Alejandrina; Escobar Castañeda, Luis A.; Carrera Villacrés, David; Bravo Yagüe, Juan CarlosNatural and anthropogenic sources contribute to arsenic contamination in water and human food chain in Andean countries. Human exposure to arsenic via rice consumption is of great concern in countries where this crop is the dominant staple food, and limited information is available on the arsenic contamination on rice in Ecuador. This work was to contribute to the lack of knowledge analysing total arsenic by hydride generation-atomic absorption spectrometry in the samples of white, brown and parboiled rice purchased in Ecuadorian markets and produced in the two main rice wetlands in Ecuador, Guayas and Los Ríos, were carried out. For the samples from Guayas, arsenic concentration in white, brown and parboiled rice were 0.174 ± 0.014, 0.232 ± 0.021, and 0.186 ± 0.017 mg/kg respectively, whereas samples of white rice from Los Ríos showed a total arsenic level of 0.258 ± 0.037 mg/kg. This last arsenic concentration exceeds recommended maximum permissible limit by the FAO/WHO. Obtained data have available to estimate the Ecuadorian dietary exposure revealing serious health risk for populationPublicación Enhancement of a Simple, Economic and Eco-Friendly Analytical Approach for the Extraction and Determination of Endocrine Disruptors from Plastics in Shrimp(MDPI, 2024-07-12) Soliz Rojas, Dulce Lucy; García González, Jorge; Paniagua González, Gema; Garcinuño Martínez, Rosa Mª; Bravo Yagüe, Juan Carlos; Fernández Hernando, PilarThe economic significance of the shrimp industry relies heavily on the comprehensive utilization of all of the shrimp’s parts. However, this importance is often threatened by common challenges such as disease and pollution, caused by prominent contaminants that are capable of exerting adverse effects either directly as physical pollutants or indirectly through the incorporation of additives or adsorbed chemicals. Among these substances are endocrine disruptors, which pose risks to both wildlife and human populations. In this study, 11 endocrine-disrupting compounds were determined (3 bisphenols, 3 phthalates, 3 pesticides, and 2 nonylphenols) through the development of a cost-effective, greener and cost-friendly method based on solid-phase matrix dispersion (MSPD) with high-performance liquid chromatography coupled with diode array detection (HPLC-DAD). Determinations were performed on different parts of the shrimp: the cephalothorax, abdomen, intestine and shell. Several variables were optimized in the extraction, separation and detection phases, resulting in average recoveries of about 90%. The limit of detection (LOD) varies depending on the analyte and matrix. At concentrations of 1 mg/kg in the cephalothorax+shells and 1.25 mg/kg in the abdomen+intestine, all compounds were detected, except for nonylphenols. The developed method has allowed the simultaneous determination of 11 endocrine disruptors in different parts of the shrimp samples. Furthermore, the MSPD has been demonstrated to be an efficacious, selective, and streamlined sample extraction method, eliminating the necessity for pretreatment steps such as centrifugation and filtration, as well as the use of large volumes of solvents.Publicación Selective extraction of diazepam and its metabolites from urine samples by a molecularly imprinted solid phase extraction (MISPE) method(MDPI, 2024-02) Gil Tejedor, Ana María; Bravo Yagüe, Juan Carlos; Paniagua González, Gema; Fernández Hernando, Pilar; Garcinuño Martínez, Rosa MªIn this research, a molecularly imprinted polymer (MIP) was synthesized by precipitation polymerization using oxazepam (OZ) as a template molecule and was subsequently applied as a selective sorbent for the extraction of diazepam (DZP) and its metabolites in urine samples using an SPE cartridge. OZ, temazepam (TZ), nordiazepam (NZ) and DZP were analyzed in the final extracts by high-performance liquid chromatography with diode array detection (HPLC-DAD). The SPE extraction steps were optimized, and the evaluation of an imprinting factor was carried out. The selectivity of the method for OZ versus structurally related benzodiazepines (BZDs), such as bromazepam (BRZ), tetrazepam (TTZ) and halazepam (HZ), was investigated. Under the optimum conditions, the proposed methodology provided good linearity in the range of 10–1500 ng/mL, with limit of detection values between 13.5 and 21.1 ng/mL and recovery levels for DZP and its metabolites from 89.0 to 93.9% (RSD ≤ 8%) at a concentration level of 1000 ng/mL. The proposed method exhibited good selectivity, precision and accuracy and was applied to the analysis of urine samples from a real case of DZP intake.Publicación Effects of UVC irradiation on polystyrene for healthcare packaging: Study by FTIR and Raman spectroscopy with thermoluminescence(Elsevier, 2024-02-14) Correcher, V.; García Guinea, Javier; Boronat Castaño, Cecilia; Bravo Yagüe, Juan CarlosThe interaction between ultraviolet C radiation (UVC) and polystyrene (PS) materials has been investigated, particularly in post-packaging irradiation processes for healthcare applications. Effective UVC penetration through PS materials, regardless of their thickness (0.16 and 0.40 mm) has been observed. However, the penetration effectiveness could be affected by the thickness of the PS material. Achieving optimal post-packaging UVC treatment requires a thorough evaluation of chemical composition and material thickness, especially in pharmaceutical and medical packaging industries. Preliminary results reveal minimal degradation in UVC-irradiated PS packaging samples, as supported by FTIR and Raman spectroscopy characterization. Minor variations could be attributed to intrinsic PS materials properties and/or their respective background, rather than the influence of UVC radiation. Consequently, PS materials exhibit resilience under the experimental conditions following UVC irradiation treatment. Furthermore, a comprehensive analysis of thermoluminescence (TL) emissions evaluates several commercial dosimeter materials for UVC radiation detection. The TLD-100 and TLD-200 dosimeters show potential as UVC detectors, displaying distinct responses linked to the non-ionizing component of UVC radiation at 310 ◦C and in the range of 150–250 ◦ C, respectively. However, the TLD-400 and GR-200 dosimeters are not suitable for UVC detection due to their spread TL emissions considering intensity and curve shape. This UVC-TL analysis consistently detects radiation in the proposed commercial dosimeter materials one-hour post-exposure, providing assurance that healthcare materials have been irradiated. Such analysis enhances reliability during extended UVC exposures, offering valuable insights for industries employing UVC-irradiated materials, particularly in healthcare applications.Publicación Effects of UVC irradiation on polystyrene for healthcare packaging: Study by FTIR and Raman spectroscopy with thermoluminescence(Elsevier, 2024-02-14) Correcher, V.; García-Guinea, J; Boronat Castaño, Cecilia; Bravo Yagüe, Juan CarlosThe interaction between ultraviolet C radiation (UVC) and polystyrene (PS) materials has been investigated, particularly in post-packaging irradiation processes for healthcare applications. Effective UVC penetration through PS materials, regardless of their thickness (0.16 and 0.40 mm) has been observed. However, the penetration effectiveness could be affected by the thickness of the PS material. Achieving optimal post-packaging UVC treatment requires a thorough evaluation of chemical composition and material thickness, especially in pharmaceutical and medical packaging industries. Preliminary results reveal minimal degradation in UVC-irradiated PS packaging samples, as supported by FTIR and Raman spectroscopy characterization. Minor variations could be attributed to intrinsic PS materials properties and/or their respective background, rather than the influence of UVC radiation. Consequently, PS materials exhibit resilience under the experimental conditions following UVC irradiation treatment. Furthermore, a comprehensive analysis of thermoluminescence (TL) emissions evaluates several commercial dosimeter materials for UVC radiation detection. The TLD-100 and TLD-200 dosimeters show potential as UVC detectors, displaying distinct responses linked to the non-ionizing component of UVC radiation at 310 ◦C and in the range of 150–250 ◦ C, respectively. However, the TLD-400 and GR-200 dosimeters are not suitable for UVC detection due to their spread TL emissions considering intensity and curve shape. This UVC-TL analysis consistently detects radiation in the proposed commercial dosimeter materials one-hour post-exposure, providing assurance that healthcare materials have been irradiated. Such analysis enhances reliability during extended UVC exposures, offering valuable insights for industries employing UVC-irradiated materials, particularly in healthcare applications.Publicación Detecting ultraviolet C radiation under polyethylene terephthalate (PET) packaging by thermoluminescence analysis using commercial dosimeters(Elsevier, 2024-03-07) Correcher, V.; Boronat Castaño, Cecilia; Bravo Yagüe, Juan CarlosFood irradiation is a proven technology that enhances food quality and safety by removing microorganisms and extending shelf life. Ultraviolet C radiation (UVC) has recently attracted interest due to its potential to inactivate foodborne pathogens. It relies on several advantages; however, there is limited research on its efficacy and safety particularly concerning food packaging materials such as polyethylene terephthalate (PET). This study reports on the effect of UVC radiation on commercial thermoluminescence dosimeters (namely, TLD-100, TLD-200, TLD-400 and GR-200) placed under PET films with different thicknesses (0.10, 0.42, and 0.60 mm). The results indicate the potential use of these materials for the detection of UVC radiation passing through the randomly selected PET samples. Fourier transform infrared spectroscopy assesses potential structural and chemical alterations in the PET induced by UVC exposure.Publicación Identification and morphological characterization of different types of plastic microparticles(Elsevier, 2024-05-15) Soliz Rojas, Dulce Lucy; Paniagua González, Gema; Muñoz Arnanz, Juan; Bravo Yagüe, Juan Carlos; Fernández Hernando, Pilar; Garcinuño Martínez, Rosa MªThe knowledge of the polymeric composition of microplastics (MPs) is interesting because offers useful information on the resistance, durability, and degradability of these materials, also allowing progress in the control of this contamination. However, there is currently a lack of reliable standardized methods for the identification, and characterization of the plastic microparticles. This work uses different techniques in a complementary manner for the identification, and characterization of MPs that more frequently are found in the environment. A total of 10 types of plastics were collected (polystyrene (PS), polyethylene terephthalate (PETE), polyethylene (PE), high- and low-density polyethylene (HDPE and LDPE, respectively), polyvinyl chloride (PVC), polypropylene (PP), polytetrafluoroethylene (PTFE), Polyamide (PA, Nylon 6,6) and poly-carbonate (PC)) and their chemical identification were analyzed by reflectance-attenuated infrared (FTIR-ATR). Furthermore, the samples were observed using light microscopy, and scan-ning electron microscopy (SEM). Also, staining with 12 different dyes was performed to improve the identification of microplastics. The results of this study revealed that PETE, PE, HDPE and LDPE, whose SEM images exhibited smoothness and flat uniformity of their surface, were not (or less) susceptible to adsorb staining solutions while PP, PA, PVC, and PTFE, were capable of adsorbing the dye solutions.